Brand Name : KACISE
Model Number : KGD-ATRS-315
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Detection Principle : Non - Dispersive Infrared (NDIR) Detection Technology
Tested Gas : Electrolyte Vapor DMC
Measuring Range : 0 - 10000ppm
Data Refresh : ≤1s
Preheating Time : <15s
Communication Method : CAN2.0B
Electrolyte Leakage Sensor KGD - ATRS - 315
Product Introduction
The KGD - ATRS - 315 electrolyte leakage sensor is a lithium - ion battery electrolyte leakage sensor developed based on Non - Dispersive Infrared (NDIR) technology. It can conduct real - time online monitoring of the gas concentration released by electrolyte leakage in the environment and output alarm signals. This sensor features high precision and excellent long - term stability.
Product Features
Technical Parameters
Items | Details |
Detection Principle | Non - Dispersive Infrared (NDIR) Detection Technology |
Tested Gas | Electrolyte Vapor DMC |
Measuring Range | 0 - 10000ppm |
Measurement Accuracy | 0 - 2000ppm: ±200ppm |
2000ppm - 10000ppm: ±10% of the reading | |
Data Refresh | ≤1s |
Preheating Time | <15s |
Communication Method | CAN2.0B |
Service Life | ≥10 years |
Protection Level | IP54 |
Operating Conditions | -40°C - 85°C, 0 - 95%RH (non - condensing) |
Supply Voltage | DC 9V - 16V, ripple <100mV |
Average Working Current | ≤30mA |
Dimensions | L70W60H19.5 (mm) |
![]() |